What was asked
PVWatts V8, run once per sub-array at 1 kW of DC capacity. One request for a single tilted row, two for an east/west pair, because PVWatts models one orientation at a time and the pair is summed.
Every parameter is sent explicitly: system capacity, tilt, azimuth, bifaciality,
ground coverage, DC/AC ratio, inverter efficiency, system losses, module type,
array type, dataset and the twelve albedo values. The engine then compares what
the API reports it received against what was sent, and fails the request if
anything was dropped or altered. That check exists because PVWatts will quietly
ignore an albedo unless use_wf_albedo=0 is also set, and a silently ignored
parameter looks exactly like a result.
What the numbers are
Everything is per kilowatt of DC capacity, for a calendar month. Multiply by the array size in kilowatts. A 12 kW array is twelve times the table.
The figures are rounded to whole kWh per kW, which is the engine's own output at this capacity. That is coarser than the model deserves, and the caveats below are much bigger than the rounding.
The month that decides it
Annual offset is the usual sales number. The question this site answers instead:
how big does the array have to be to cover the weakest month?
For a monthly usage profile u and a per-kW yield y:
kW = max over the twelve months of ( u[m] / y[m] )
For an even load that maximum always falls in the lowest-yield month, which is why the tables mark it. For a load that is higher in winter than summer — a heat pump, a well pump, a house full of people in January — the maximum can fall in a different month, and the arithmetic above still holds.
Albedo is an assumption
A bifacial panel gets extra output from light reflected off the ground. The ground reflectance is therefore one of the most influential inputs in the model, and one of the least measured. Two profiles are published, side by side, so the dependence is visible rather than buried:
- Grass, 0.22 — a flat, year-round value, close to what PVWatts' own weather file uses.
- Snow, 0.70 Nov–Mar — a winter-weighted assumption, not a measurement of any particular winter.
The difference between the two columns in January is the size of that assumption. It is larger than most of the other choices on this page.
What the model leaves out
- Shading. Rows, trees, buildings, terrain. Real sites are worse.
- Snow lying on the panels. The snow profile is ground albedo, not a cover model. A covered module makes nothing.
- Soiling. Dust, pollen, bird lime.
- Module mismatch, wiring losses, connector losses. The 14% system loss is a single number standing in for all of them.
- Battery round-trip, inverter standby, backup behaviour.
- Cost, payback, incentives, equipment. Not measurements, and not here.
- Steep-tilt bifacial behaviour. PVWatts' bifacial model is least confident at the steepest tilts, which is precisely the geometry this site leads with. The 90° column is the one to trust least.
The band
Treat every figure as ±15%. Two decimals in a table imply a precision the model does not have; the rounding is for reading, not for believing. The numbers are useful for comparing one geometry against another at the same place, which is what they are published for.