Method

What was asked

PVWatts V8, run once per sub-array at 1 kW of DC capacity. One request for a single tilted row, two for an east/west pair, because PVWatts models one orientation at a time and the pair is summed.

Every parameter is sent explicitly: system capacity, tilt, azimuth, bifaciality, ground coverage, DC/AC ratio, inverter efficiency, system losses, module type, array type, dataset and the twelve albedo values. The engine then compares what the API reports it received against what was sent, and fails the request if anything was dropped or altered. That check exists because PVWatts will quietly ignore an albedo unless use_wf_albedo=0 is also set, and a silently ignored parameter looks exactly like a result.

What the numbers are

Everything is per kilowatt of DC capacity, for a calendar month. Multiply by the array size in kilowatts. A 12 kW array is twelve times the table.

The figures are rounded to whole kWh per kW, which is the engine's own output at this capacity. That is coarser than the model deserves, and the caveats below are much bigger than the rounding.

The month that decides it

Annual offset is the usual sales number. The question this site answers instead:

how big does the array have to be to cover the weakest month?

For a monthly usage profile u and a per-kW yield y:

kW = max over the twelve months of ( u[m] / y[m] )

For an even load that maximum always falls in the lowest-yield month, which is why the tables mark it. For a load that is higher in winter than summer — a heat pump, a well pump, a house full of people in January — the maximum can fall in a different month, and the arithmetic above still holds.

Albedo is an assumption

A bifacial panel gets extra output from light reflected off the ground. The ground reflectance is therefore one of the most influential inputs in the model, and one of the least measured. Two profiles are published, side by side, so the dependence is visible rather than buried:

The difference between the two columns in January is the size of that assumption. It is larger than most of the other choices on this page.

What the model leaves out

The band

Treat every figure as ±15%. Two decimals in a table imply a precision the model does not have; the rounding is for reading, not for believing. The numbers are useful for comparing one geometry against another at the same place, which is what they are published for.

Declared geometry

Declared geometry, as sent. Each tilt/azimuth pair is one equal-capacity sub-array.
Id Tilt Azimuth Bifaciality Note
vertical-ew 90° + 90° 90° + 270° 0.7 Two equal sub-arrays at 90° tilt, one facing east and one facing west. The geometry people ask about for snow shedding and for land that has to do two jobs. This site measures the output; it does not test either claim.
south-60 60° 180° 0.7 A steep single row facing south. The winter-weighted comparison to the vertical array.
south-30 30° 180° 0.7 The usual fixed-tilt angle near this latitude. Annual-weighted, not winter-weighted.

Every parameter sent

One row of data/yield.json, reproduced. The engine refuses a response that does not echo each parameter back, so these are values the model confirms it received, not values this site intended to send.

Where this came from

Site
Lebanon, Missouri · 37.6807, -92.6638
Climate station
NSRDB cell 790759, Missouri
Station distance
1.1 km
Weather data
NSRDB PSM V3 GOES tmy-2020 3.2.0
Model
PVWatts 8.5.0 · SSC 280
Requested
2026-11-25
Endpoint
https://developer.nlr.gov/api/pvwatts/v8.json
Dataset
nsrdb
System losses
14%
DC/AC ratio
1.2
Ground coverage
0.4
Inverter efficiency
96%
Engine
vsolar 0.3.0

Reproducing it

The engine is a Go program in this repository. It fetches 2 reference sub-arrays at 1 kW and multiplies. Regenerating rewrites data/yield.json; the build refuses to publish it unless every row matches the geometry and albedo it is filed under.

NLR_API_KEY=... npm run generate
npm run check
npm run deploy

The API key stays on the machine that runs the generator. The deployed site makes no calls.